Araştırma Makalesi
BibTex RIS Kaynak Göster

The Effect of Maximum Power Point Tracking on Efficiency in Photovoltaic Solar Panel Systems

Yıl 2020, Cilt: 10 Sayı: 4, 2496 - 2507, 15.12.2020
https://doi.org/10.21597/jist.729926

Öz

In solar energy systems, due to the low efficiency in energy conversion, efforts to increase efficiency have gained importance today. Maximum Power Point Tracking (MPPT) systems have been developed to use solar energy systems at maximum efficiency. In this study, the effect of a frequently used maximum power point tracking algorithm on efficiency is investigated. Using Matlab/Simulink, a system that includes a solar cell module and Boost DC-DC converter is designed to detect the maximum power point in variable atmospheric conditions. This system is operated with maximum power point tracking unit and without maximum power point tracking unit, and the obtained results and their effects on efficiency are compared. The system has been studied in three different situations. In the inferences obtained, it was observed that the efficiency increased from 72.6% to 92.95% in the first working condition, the efficiency increased from 90.59% to 96.43% in the second working condition, and the yield increased from 92.27% to 94.46% in the third working condition.

Kaynakça

  • Altın N., Yıldırımoğlu T., 2011. Labview/Matlab Tabanlı Maksimum Güç Noktasını Takip Edebilen Fotovoltaik Sistem Simülatörü. Politeknik Dergisi, 14,271-280.
  • Basoglu M.E., Cakir B., 2016, “Comparisons of MPPT performances of isolated and non-isolated DC-DC converters by using a new approach. Renewable & Sustainable Energy Reviews, 60, 1100-1113.
  • Boukebbous S.E. et al.; 2019. High voltage gain quasi Z source DC – DC converter contribution to photovoltaic systems. 4th International Conference on Power Electronics and their Applications (ICPEA), Turkey.
  • Cristaldi L., Faifer M., Rossi M., Toscani S., 2013, “A New Approach to Maximum Power Point Tracking for Photovoltaic Panels”, International Conference on Clean Electrical Power, 461-465.
  • Deveci O., Kanakoğlu C., 2014. Bir Fotovoltaik Sistemden Değisken Güneş Işınım Değerlerinde Maksimum Güç ve Sabit DA Gerilim Elde Edilebilmesine Yönelik DA/DA Dönüstürücü ve Kontrolcü Tasarımı”, TOK Bildiri Kitabı.
  • Elgendy M.A., Zahawi B., 2009, “Dynamic Behaviour of DC Motor-Based Photovoltaic Pumping Systems under Searching MPPT Algorithms”, Int. Conference on Power Engineering, Energy and Electrical Drives.
  • Esram T., Chapman PL., 2007, “Comparison of Photovoltaic Array Maximum Power Point Tracking Techniques”, IEEE Trans. on Energy Convers., 22, 439-449.
  • Giovanni S., Giovanni P., 2005, “Optimization of Perturb and Observe Maximum Power Point Tracking Method”, Balkan Journal of Elektrical & Computer Engineering.
  • Gupta PP., Kishore GI.; Tripathi RK., 2019, “Implementing High Gain DC-DC Converter with Switched Capacitor for PV System”, Innovations in Power and Advanced Computing Technologies (i-PACT), India.
  • Ibnelouad A.; et al.; 2017, “A Comprehensive Comparison of the Classic and Intelligent Behavior MPPT Techniques for PV Systems”, 14th International Multi-Conference on Systems, Signals & Devices (SSD), Morocco.
  • Jiang Y., Qahouq JA., Haskew TA., 2013, “Adaptive Step Size with Adaptive-Perturbation-Frequency Digital MPPT Controller for a Single-Sensor Photovoltaic Solar System”, IEEE Trans. Power Electron., 28, 3195-3204.
  • Kabala M., 2017, “Application of Distributed DC/DC Electronics in Photovoltaic Systems”, Master Thesis, Colorado State University, Fort Collins, Colorado,170.
  • Kırcıoğlu O., Yıldız AB., 2015, “Fotovoltaik Panelin Tek Diyotlu Eşdeğer Devresine Ait Büyük Sinyal Analizi”, TMMOB Elektrik Mühendisleri Odası Enerji Verimliliği ve Kalitesi Sempozyumu.
  • Koizumi H., Kurokawa K., 2005, “A Novel Maximum Power Point Tracking Method for PV Module Integrated Converter”, 36th IEEE Power Electronics Specialists Conference, (PESC'05), 2081-2086, USA.
  • Kumar S.; Sahu HS.; Nayak SK.; 2019, “Estimation of MPP of a Double Diode Model PV Module From Explicit I-V Characteristic”, IEEE Transactions on Industrial Electronics, Vol.66, Issue 9.pp.7032-4042
  • Mathew TM; Rakhee R.; 2019, “Non-Isolated High Gain DC-DC Converter for PV Applications with Closed Loop Control”,2nd Int. Conference on Intelligent Computing, Instrumentation and Control Technologies (ICICICT), India.
  • Nakir İ., 2007, “Fotovoltaik Güneş Panellerinde GTS ve MGTS Kullanarak Verimliliğin Arttırılması”, Yüksek Lisans Tezi, Yıldız Teknik Üniversitesi, Fen Bilimleri Enstitüsü, İstanbul,75.
  • Onat N., Ersöz S., 2009, “Fotovoltaik Sistemlerde Maksimum Güç Noktası İzleyici Algoritmalarının Karşılaştırılması”, V. Yenilenebilir Enerji Kaynakları Sempozyumu, Diyarbakır.
  • Yadav I.; Maurya SK.; 2020, “Modelling and Analyzing of DC-DC Converter for Solar Pump Applicaitons”, Int. Conference on Power Electronics & IoT Applications in Renewable Energy and its Control, India.

Fotovoltaik Güneş Paneli Sistemlerinde Maksimum Güç Noktası İzleyicisinin Verime Etkisi

Yıl 2020, Cilt: 10 Sayı: 4, 2496 - 2507, 15.12.2020
https://doi.org/10.21597/jist.729926

Öz

Güneş enerjisi sistemlerinde, enerji dönüşümündeki verimliliğin düşük olması nedeniyle, günümüzde verimi arttırmaya yönelik çalışmalar önem kazanmıştır. Güneş enerjisi sistemlerini maksimum verimde kullanmak için, Maksimum Güç Noktası İzleyicisi (MGNİ) sistemleri geliştirilmiştir. Bu çalışmada, sık kullanılan bir MGNİ algoritmasının verime etkisi incelenmiştir. Matlab/Simulink ortamında güneş pili modülü ve yükselten DA–DA dönüştürücü içeren, değişken ortam koşullarında maksimum güç noktasını tespit eden bir sistem tasarlanmıştır. Bu sistem, MGNİ birimi olmadan ve MGNİ birimi olması durumda çalıştırılarak elde edilen sonuçlar ve verime etkileri karşılaştırılmıştır. Sistem üç farklı durumda incelenmiştir. Elde edilen çıkarımlarda maksimum güç noktası izleyicisi varken birinci çalışma koşulunda verim %72.6’dan %92.95’e, ikinci çalışma durumunda verim %90.59’dan %96.43’e ve üçüncü çalışma durumunda verim %92.27’den %94.46’ya yükseldiği gözlemlenmiştir.

Kaynakça

  • Altın N., Yıldırımoğlu T., 2011. Labview/Matlab Tabanlı Maksimum Güç Noktasını Takip Edebilen Fotovoltaik Sistem Simülatörü. Politeknik Dergisi, 14,271-280.
  • Basoglu M.E., Cakir B., 2016, “Comparisons of MPPT performances of isolated and non-isolated DC-DC converters by using a new approach. Renewable & Sustainable Energy Reviews, 60, 1100-1113.
  • Boukebbous S.E. et al.; 2019. High voltage gain quasi Z source DC – DC converter contribution to photovoltaic systems. 4th International Conference on Power Electronics and their Applications (ICPEA), Turkey.
  • Cristaldi L., Faifer M., Rossi M., Toscani S., 2013, “A New Approach to Maximum Power Point Tracking for Photovoltaic Panels”, International Conference on Clean Electrical Power, 461-465.
  • Deveci O., Kanakoğlu C., 2014. Bir Fotovoltaik Sistemden Değisken Güneş Işınım Değerlerinde Maksimum Güç ve Sabit DA Gerilim Elde Edilebilmesine Yönelik DA/DA Dönüstürücü ve Kontrolcü Tasarımı”, TOK Bildiri Kitabı.
  • Elgendy M.A., Zahawi B., 2009, “Dynamic Behaviour of DC Motor-Based Photovoltaic Pumping Systems under Searching MPPT Algorithms”, Int. Conference on Power Engineering, Energy and Electrical Drives.
  • Esram T., Chapman PL., 2007, “Comparison of Photovoltaic Array Maximum Power Point Tracking Techniques”, IEEE Trans. on Energy Convers., 22, 439-449.
  • Giovanni S., Giovanni P., 2005, “Optimization of Perturb and Observe Maximum Power Point Tracking Method”, Balkan Journal of Elektrical & Computer Engineering.
  • Gupta PP., Kishore GI.; Tripathi RK., 2019, “Implementing High Gain DC-DC Converter with Switched Capacitor for PV System”, Innovations in Power and Advanced Computing Technologies (i-PACT), India.
  • Ibnelouad A.; et al.; 2017, “A Comprehensive Comparison of the Classic and Intelligent Behavior MPPT Techniques for PV Systems”, 14th International Multi-Conference on Systems, Signals & Devices (SSD), Morocco.
  • Jiang Y., Qahouq JA., Haskew TA., 2013, “Adaptive Step Size with Adaptive-Perturbation-Frequency Digital MPPT Controller for a Single-Sensor Photovoltaic Solar System”, IEEE Trans. Power Electron., 28, 3195-3204.
  • Kabala M., 2017, “Application of Distributed DC/DC Electronics in Photovoltaic Systems”, Master Thesis, Colorado State University, Fort Collins, Colorado,170.
  • Kırcıoğlu O., Yıldız AB., 2015, “Fotovoltaik Panelin Tek Diyotlu Eşdeğer Devresine Ait Büyük Sinyal Analizi”, TMMOB Elektrik Mühendisleri Odası Enerji Verimliliği ve Kalitesi Sempozyumu.
  • Koizumi H., Kurokawa K., 2005, “A Novel Maximum Power Point Tracking Method for PV Module Integrated Converter”, 36th IEEE Power Electronics Specialists Conference, (PESC'05), 2081-2086, USA.
  • Kumar S.; Sahu HS.; Nayak SK.; 2019, “Estimation of MPP of a Double Diode Model PV Module From Explicit I-V Characteristic”, IEEE Transactions on Industrial Electronics, Vol.66, Issue 9.pp.7032-4042
  • Mathew TM; Rakhee R.; 2019, “Non-Isolated High Gain DC-DC Converter for PV Applications with Closed Loop Control”,2nd Int. Conference on Intelligent Computing, Instrumentation and Control Technologies (ICICICT), India.
  • Nakir İ., 2007, “Fotovoltaik Güneş Panellerinde GTS ve MGTS Kullanarak Verimliliğin Arttırılması”, Yüksek Lisans Tezi, Yıldız Teknik Üniversitesi, Fen Bilimleri Enstitüsü, İstanbul,75.
  • Onat N., Ersöz S., 2009, “Fotovoltaik Sistemlerde Maksimum Güç Noktası İzleyici Algoritmalarının Karşılaştırılması”, V. Yenilenebilir Enerji Kaynakları Sempozyumu, Diyarbakır.
  • Yadav I.; Maurya SK.; 2020, “Modelling and Analyzing of DC-DC Converter for Solar Pump Applicaitons”, Int. Conference on Power Electronics & IoT Applications in Renewable Energy and its Control, India.
Toplam 19 adet kaynakça vardır.

Ayrıntılar

Birincil Dil Türkçe
Konular Elektrik Mühendisliği
Bölüm Elektrik Elektronik Mühendisliği / Electrical Electronic Engineering
Yazarlar

Ufuk Badak 0000-0002-2008-6337

Ali Bekir Yıldız 0000-0003-4043-7859

Yayımlanma Tarihi 15 Aralık 2020
Gönderilme Tarihi 30 Nisan 2020
Kabul Tarihi 26 Ağustos 2020
Yayımlandığı Sayı Yıl 2020 Cilt: 10 Sayı: 4

Kaynak Göster

APA Badak, U., & Yıldız, A. B. (2020). Fotovoltaik Güneş Paneli Sistemlerinde Maksimum Güç Noktası İzleyicisinin Verime Etkisi. Journal of the Institute of Science and Technology, 10(4), 2496-2507. https://doi.org/10.21597/jist.729926
AMA Badak U, Yıldız AB. Fotovoltaik Güneş Paneli Sistemlerinde Maksimum Güç Noktası İzleyicisinin Verime Etkisi. Iğdır Üniv. Fen Bil Enst. Der. Aralık 2020;10(4):2496-2507. doi:10.21597/jist.729926
Chicago Badak, Ufuk, ve Ali Bekir Yıldız. “Fotovoltaik Güneş Paneli Sistemlerinde Maksimum Güç Noktası İzleyicisinin Verime Etkisi”. Journal of the Institute of Science and Technology 10, sy. 4 (Aralık 2020): 2496-2507. https://doi.org/10.21597/jist.729926.
EndNote Badak U, Yıldız AB (01 Aralık 2020) Fotovoltaik Güneş Paneli Sistemlerinde Maksimum Güç Noktası İzleyicisinin Verime Etkisi. Journal of the Institute of Science and Technology 10 4 2496–2507.
IEEE U. Badak ve A. B. Yıldız, “Fotovoltaik Güneş Paneli Sistemlerinde Maksimum Güç Noktası İzleyicisinin Verime Etkisi”, Iğdır Üniv. Fen Bil Enst. Der., c. 10, sy. 4, ss. 2496–2507, 2020, doi: 10.21597/jist.729926.
ISNAD Badak, Ufuk - Yıldız, Ali Bekir. “Fotovoltaik Güneş Paneli Sistemlerinde Maksimum Güç Noktası İzleyicisinin Verime Etkisi”. Journal of the Institute of Science and Technology 10/4 (Aralık 2020), 2496-2507. https://doi.org/10.21597/jist.729926.
JAMA Badak U, Yıldız AB. Fotovoltaik Güneş Paneli Sistemlerinde Maksimum Güç Noktası İzleyicisinin Verime Etkisi. Iğdır Üniv. Fen Bil Enst. Der. 2020;10:2496–2507.
MLA Badak, Ufuk ve Ali Bekir Yıldız. “Fotovoltaik Güneş Paneli Sistemlerinde Maksimum Güç Noktası İzleyicisinin Verime Etkisi”. Journal of the Institute of Science and Technology, c. 10, sy. 4, 2020, ss. 2496-07, doi:10.21597/jist.729926.
Vancouver Badak U, Yıldız AB. Fotovoltaik Güneş Paneli Sistemlerinde Maksimum Güç Noktası İzleyicisinin Verime Etkisi. Iğdır Üniv. Fen Bil Enst. Der. 2020;10(4):2496-507.