EN
TR
ANALYSING THE GENERATION PERFORMANCE OF A SOLAR POWER PLANT UNDER DIFFERENT TILT AND AZIMUTH ANGLE SCENARIOS
Abstract
In this study, the production performance of a 14.82 kWp / 10 kWe solar power plant was analyzed in detail under different tilt and azimuth angle scenarios. The plant's annual electricity generation was calculated using a computer-aided analysis program. As per relevant regulations, when the generated power exceeds the contract power during certain hours of the day, energy injection into the grid is restricted, and the power output is limited. In the simulation study, the panel capacity of the plant was designed to be 48.2% higher than the electrical connection capacity, and different loading scenarios were evaluated. The study analyzed nine panel layout scenarios, considering various tilt and orientation combinations. The optimal configuration was determined as 10% of the panels facing east (10°), 10% facing west (10°), and 80% facing south (20°), resulting in an annual net electricity generation of 23,831 kWh. Additionally, the environmental impacts of energy production were assessed, and it was calculated that the best scenario prevents 15.12 tons of CO₂ emissions per year. This study highlights the critical role of panel placement optimization in photovoltaic power plants to enhance energy production efficiency and minimize power limitations.
Keywords
Kaynakça
- Arslan, M., & Çunkaş, M. (2024). An experimental study on determination of optimal tilt and orientation angles in photovoltaic systems. Journal of Engineering Research.(Article in Press) https://doi.org/10.1016/j.jer.2024.07.015 .
- Atlım, F., Esen, B., & Demirtaş, M. (2019). Balıkesir ilinde farklı iki GES tesisinin panel yerleşimi açısından verimliliklerinin karşılaştırılması. Balıkesir Üniversitesi Fen Bilimleri Enstitüsü Dergisi, 21(2), 679-696. DOI: 10.25092/baunfbed.636967.
- Bakirci, K. (2012). Correlations for optimum tilt angles of solar collectors: a case study in Erzurum, Turkey. Energy Sources, Part A: Recovery, Utilization, and Environmental Effects, 34(11), 983-993. DOI: 10.1080/15567031003735279.
- Barbón, A., Bayón-Cueli, C., Bayón, L., & Rodríguez-Suanzes, C. (2022). Analysis of the tilt and azimuth angles of photovoltaic systems in non-ideal positions for urban applications. Applied Energy, 305, 117802. https://doi.org/10.1016/j.apenergy.2021.117802
- Boztepe, M. (2017). Fotovoltaik güç sistemlerinde verimliliği etkileyen parametreler. EMO İzmir Şubesi Aylık Bülteni, 321, 13-17.
- Dincer, F. , & Ozer, E. (2023). Assessing the potential of a rooftop grid-connected photovoltaic system for Gaziantep Islamic Science and Technology University/Turkey. Jordan Journal of Electrical Engineering, 9(2), 149-165. http://doi.org/10.5455/jjee.204-1670146602 .
- EPDK (Enerji Piyasası Düzenleme Kurumu) . Elektrik Piyasası Aylık Sektör Raporu Listesi-2024 Yılı Elektrik Piyasası Eylül Ayı Sektör Raporu. (2024). https://www.epdk.gov.tr/Detay/Icerik/3-0-23/aylik-sektor-raporu Erişim tarihi: 28.11.2024
- ETKB (Enerji ve Tabii Kaynaklar Bakanlığı). Bilgi Merkezi- Güneş. (2024a). https://enerji.gov.tr/bilgi-merkezi-enerji-gunes Erişim tarihi: 05.11.2024
Ayrıntılar
Birincil Dil
Türkçe
Konular
Fotovoltaik Güç Sistemleri
Bölüm
Araştırma Makalesi
Yayımlanma Tarihi
3 Haziran 2025
Gönderilme Tarihi
2 Aralık 2024
Kabul Tarihi
14 Şubat 2025
Yayımlandığı Sayı
Yıl 1970 Cilt: 28 Sayı: 2
APA
Dinçer, F., & Özer, E. (2025). FARKLI EĞİM VE AZİMUT AÇISI SENARYOLARI ALTINDA GÜNEŞ ENERJİSİ SANTRALİNİN ÜRETİM PERFORMANSLARININ ANALİZİ. Kahramanmaraş Sütçü İmam Üniversitesi Mühendislik Bilimleri Dergisi, 28(2), 644-659. https://doi.org/10.17780/ksujes.1595056
Cited By
TEK VE ÇİFT YÜZLÜ FOTOVOLTAİK SİSTEMLERİN SİMÜLASYON TABANLI PERFORMANS DEĞERLENDİRİLMESİ: OSMANİYE KORKUT ATA ÜNİVERSİTESİ UYGULAMASI
Kahramanmaraş Sütçü İmam Üniversitesi Mühendislik Bilimleri Dergisi
https://doi.org/10.17780/ksujes.1715532