Betonarme Binalarda Kısa Kolon Oluşumunda Dolgu Duvar Etkisi: Örnek Çalışma

Cilt: 19 Sayı: 2 9 Eylül 2016
PDF İndir
EN TR

Masonry Infill Walls Effect In Short Column Formation In Rc Buildings: A Case Study

Öz

The analyses of infill frame structures are generally done ignoring the presence of brick masonry in the analytical models but it is a prevalent mistake. Behaviors of such buildings vary significantly during the earthquake events. The lateral resisting capacity of infill wall actually restricts the column only up to the wall height but above the wall height, the free column deforms easily. In this paper, the effect of infill wall in formation of short column at military aid watchtower in Turkey has been analyzed and the analysis result compared with effect of earthquake that have been seen after earthquake

Kaynakça

  1. Mosalam, K. M., and Gunay, S. (2015). "Progressive Collapse Analysis of Reinforced Concrete Frames with Unreinforced Masonry Infill Walls
  2. Interaction." Earthq Spectra, 31(2), 921-943.
  3. Uva, G., Porco, F., and Fiore, A. (2012). "Appraisal of masonry infill walls effect in the seismic response of RC framed buildings: A case study." Eng Struct, 34, 514-526.
  4. (CEN. Eurocode -2005). "Design of structures for earthquake resistance. Part 3: Assessment and retrofitting of buildings."Brussels.
  5. Negro P, and A., C. (1997). "Irregularities induced by non-structural masonry panels in framed buildings." Eng Struct, 10.
  6. Dolsek, M., and Fajfar, P. (2005). "Simplified non-linear seismic analysis of infilled reinforced concrete frames." Earthq Eng Struct D, 34(1), 49-66. [6]. Khalilzadeh Vahidi, E., and Mokhtari Malekabadi, M. (2009). "Conceptual Investigation of Short-Columns and Masonary Infill Frames Effect in the Earthquakes." International Journal of Civil, Environmental,
  7. Architectural Engineering 3(11).
  8. Prachand Man, P., Prajwal, L. P., and Ramesh, K. M. (2012). "Lateral strength of partial masonry infill wall in concrete frame under static load." Journal of Civil Engineering (IEB) 40(1), 66-77.

Ayrıntılar

Birincil Dil

Türkçe

Konular

-

Bölüm

-

Yayımlanma Tarihi

9 Eylül 2016

Gönderilme Tarihi

21 Nisan 2016

Kabul Tarihi

-

Yayımlandığı Sayı

Yıl 2016 Cilt: 19 Sayı: 2

Kaynak Göster

APA
Yadollahı, M. M., Benli, A., & Varolgüneş, S. (2016). Betonarme Binalarda Kısa Kolon Oluşumunda Dolgu Duvar Etkisi: Örnek Çalışma. Kahramanmaraş Sütçü İmam Üniversitesi Mühendislik Bilimleri Dergisi, 19(2), 78-83. https://doi.org/10.17780/ksujes.16070
AMA
1.Yadollahı MM, Benli A, Varolgüneş S. Betonarme Binalarda Kısa Kolon Oluşumunda Dolgu Duvar Etkisi: Örnek Çalışma. Kahramanmaraş Sütçü İmam Üniversitesi Mühendislik Bilimleri Dergisi. 2016;19(2):78-83. doi:10.17780/ksujes.16070
Chicago
Yadollahı, Mehrzad Mohabbi, Ahmet Benli, ve Sadık Varolgüneş. 2016. “Betonarme Binalarda Kısa Kolon Oluşumunda Dolgu Duvar Etkisi: Örnek Çalışma”. Kahramanmaraş Sütçü İmam Üniversitesi Mühendislik Bilimleri Dergisi 19 (2): 78-83. https://doi.org/10.17780/ksujes.16070.
EndNote
Yadollahı MM, Benli A, Varolgüneş S (01 Eylül 2016) Betonarme Binalarda Kısa Kolon Oluşumunda Dolgu Duvar Etkisi: Örnek Çalışma. Kahramanmaraş Sütçü İmam Üniversitesi Mühendislik Bilimleri Dergisi 19 2 78–83.
IEEE
[1]M. M. Yadollahı, A. Benli, ve S. Varolgüneş, “Betonarme Binalarda Kısa Kolon Oluşumunda Dolgu Duvar Etkisi: Örnek Çalışma”, Kahramanmaraş Sütçü İmam Üniversitesi Mühendislik Bilimleri Dergisi, c. 19, sy 2, ss. 78–83, Eyl. 2016, doi: 10.17780/ksujes.16070.
ISNAD
Yadollahı, Mehrzad Mohabbi - Benli, Ahmet - Varolgüneş, Sadık. “Betonarme Binalarda Kısa Kolon Oluşumunda Dolgu Duvar Etkisi: Örnek Çalışma”. Kahramanmaraş Sütçü İmam Üniversitesi Mühendislik Bilimleri Dergisi 19/2 (01 Eylül 2016): 78-83. https://doi.org/10.17780/ksujes.16070.
JAMA
1.Yadollahı MM, Benli A, Varolgüneş S. Betonarme Binalarda Kısa Kolon Oluşumunda Dolgu Duvar Etkisi: Örnek Çalışma. Kahramanmaraş Sütçü İmam Üniversitesi Mühendislik Bilimleri Dergisi. 2016;19:78–83.
MLA
Yadollahı, Mehrzad Mohabbi, vd. “Betonarme Binalarda Kısa Kolon Oluşumunda Dolgu Duvar Etkisi: Örnek Çalışma”. Kahramanmaraş Sütçü İmam Üniversitesi Mühendislik Bilimleri Dergisi, c. 19, sy 2, Eylül 2016, ss. 78-83, doi:10.17780/ksujes.16070.
Vancouver
1.Mehrzad Mohabbi Yadollahı, Ahmet Benli, Sadık Varolgüneş. Betonarme Binalarda Kısa Kolon Oluşumunda Dolgu Duvar Etkisi: Örnek Çalışma. Kahramanmaraş Sütçü İmam Üniversitesi Mühendislik Bilimleri Dergisi. 01 Eylül 2016;19(2):78-83. doi:10.17780/ksujes.16070

Cited By

DİZİNLENME ve ARŞİVLEME

download?token=eyJhdXRoX3JvbGVzIjpbXSwiZW5kcG9pbnQiOiJqb3VybmFsIiwib3JpZ2luYWxuYW1lIjoiaW1hZ2UucG5nIiwicGF0aCI6IjAzNTkvYmZjYS81YjQyLzY5ZjFkM2E4NWY2YWY3Ljg1NjQ2NDgxLnBuZyIsImV4cCI6MTc3NzQ1OTY0MCwibm9uY2UiOiI1NTUzYmJiN2U5NGNkMjdkYWNhMTRlMDZiYjc1OTY4NCJ9.nCVoSJClEIC9bWK5gGCmjHyTNRz2N0DhYKVJzJZR9Bs

 

download?token=eyJhdXRoX3JvbGVzIjpbXSwiZW5kcG9pbnQiOiJqb3VybmFsIiwib3JpZ2luYWxuYW1lIjoiaW1hZ2UucG5nIiwicGF0aCI6Ijg5YmUvODZlOC8wYzY0LzY5ZjFkNWE4MWJmYzY0LjM0OTM2NzM1LnBuZyIsImV4cCI6MTc3NzQ2MDE1Miwibm9uY2UiOiI3OWE1Mzk0OWRhMTk0Mjg0OGYzZTUxOWQyNTU5MjdjMSJ9.XxqhJ36woCZcO1DV_I9Mogpgg86-bwM454jQiOcqpS0 

Bu eser, Creative Commons Atıf 4.0 Uluslararası Lisansı ile lisanslanmıştır.